My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Building Code Board of Appeals Agenda and Packet 2024 11 13
PORTAL
>
BOARDS COMMISSIONS COMMITTEES RECORDS (20.000)
>
BUILDING CODE BOARD OF APPEALS
>
2024 Building Code Board of Appeals Agendas and Packets
>
Building Code Board of Appeals Agenda and Packet 2024 11 13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/6/2024 2:40:00 PM
Creation date
11/6/2024 9:09:38 AM
Metadata
Fields
Template:
City Council Records
Meeting Date
11/13/2024
Doc Type
Boards Commissions Committees Records
Quality Check
11/6/2024
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Building Code Board of Appeals <br />Agenda <br />September 25, 2024 <br />Page 14 of 56 <br />10. Locking devices are permitted on doors to balconies, decks or <br />other exterior spaces serving individual dwelling or sleeping units. <br />Sec.15.04.080.- Section 1031.1 Amended —General emergency escape <br />and rescue. <br />Section 1030.1 of the International Building Code is amended to <br />read as follows: <br />1030.1 General. In addition to the means of egress required by this <br />chapter, emergency escape and rescue openings shall be provided in the <br />following occupancies: <br />1. Group R-2 occupancies located in stories with only <br />one exit or access to only one exit as permitted by Tables 1006.3.4(1) and <br />1006.3.4(2). <br />2. Group R-3 and R-4 occupancies. Basements and <br />sleeping rooms below the fourth story above grade plane shall have not <br />fewer than one exterior emergency escape and rescue opening in <br />accordance with this section. Where basements contain one or more <br />sleeping rooms, emergency escape and rescue openings shall be required <br />in each sleeping room, but also be required in adjoining areas of the <br />basement. Such openings shall open directly into a public way or to a yard <br />or court that opens to a public way. <br />3. Exceptions: Basements with a ceiling height of less <br />than 80 inches (2032 mm) shall not be required to have emergency escape <br />and rescue openings. Emergency escape and rescue openings are not <br />required from basements or sleeping rooms that have an exit door or exit <br />access door that opens directly into a public way or to a yard, court or <br />exterior exit balcony that opens to a public way. Basements without <br />habitable spaces and having not more than 200 square feet (18.6 m2) in <br />floor area shall not be required to have emergency escape and rescue <br />openings. <br />Sec.15.04.090.- Section 1604.8.3 amended —Decks. <br />Section 1604.8.3 of the International Building Code is amended to <br />read as follows: <br />1604.8.3 Decks. Decks that are structurally supported from an <br />existing structure shall be engineered by a structural engineer that is <br />licensed with the State of Colorado. Where supported by attachment to an <br />
The URL can be used to link to this page
Your browser does not support the video tag.