Laserfiche WebLink
Kimley»>Horn <br />Utility Depictions Per ASCE/UESI/CI 38-22 Standard <br />Page <br />T2ue field crews will use tablets or laptops to field sketch line work and structures while conducting the <br />investigation process. This sketch will consist of notes from the investigation. The field sketch will be <br />provided to the survey team to ensure all field marks are accurately collected. Information will be reviewed <br />in the office to ensure the data collected is accurate. The surveyed data will be reconciled with the utility <br />records and other supporting information, and each utility segment is assigned a Quality Level by a <br />Colorado PE in responsible charge of the investigation. <br />QA/QC <br />T2ue will generate and review permits and Maintenance of Traffic plans. T2ue will review the field <br />investigation documents and records collected as a part of records research. Use professional judgment to <br />assign quality levels and horizontal positions to subsurface utilities. T2ue will consolidate and draft the <br />collected field information in a SUE deliverable. <br />Review Findings <br />T2ue will assist in the evaluation of utilities and make recommendations for potential major utility conflicts. <br />Quality Level A (QLA) <br />T2ue will perform Quality Level A test holes as outlined below to determine the location and depth of the <br />existing utility lines. T2ue will use minimally intrusive excavation techniques, which ensure the safety of the <br />excavation and the integrity of the utility line to be documented. Other lines which may be encountered <br />during the excavation will be noted. The excavation will be conducted by means of air or hydro vacuum <br />excavation equipment manufactured specifically for this purpose. To help minimize the number of test holes <br />required, T2ue will lay out the holes and re -designate the associated utility prior to excavation. Test Hole <br />Data Reports will be signed and sealed by a professional engineer and will consist of project -specific <br />coordinates, depth of the utility from the existing ground, material, and size of the utility found. <br />Documentation <br />Deliverables produced from the Subsurface Utility Engineering (SUE) investigation will be: <br />• A drawing showing the location of the utilities within the investigation area at the achieved ASCE <br />38-22 Quality Level. Utility line work will be depicted according to the standard APWA utility colors. <br />This drawing will be a digital 11" x 17" PDF plan set that is signed and sealed by a licensed PE. <br />• Invert elevations that reference the Client's specified project datum (if provided). <br />• An electronic file containing utility line work in AutoCAD format. <br />• Test hole Summary Reports presented in electronic format signed and sealed by a licensed PE. <br />Test Hole Data Reports will consist of project -specific coordinates, depth of the utility from the <br />existing ground, material, and size of the utility found. The data collected as a part of the QLA <br />investigation will then be incorporated into the existing utility drawing. <br />• A utility contact list to consist of the utility provider, contact name, email address, and phone <br />numbers shown in the utility general notes and specifications. <br />kimley-horn.com <br />11800 Ridge Parkway, Suite 200, Broomfield, CO 80021 <br />303 228 2300 <br />